A Validated Rp – Hplc Method For Simultaneous Estimation Of Vitamin A And Vitamin E In Multivitamin Tablet Dosage Form

Authors

  • ANURADHA.S.N. Masterskill university college of health science, Ipoh, Perak, Malaysia.
  • ARUNKUMAR.S FR&D Drreddys laboratory Hydrabad. INDIA.

Keywords:

Vitamin A, Vitamin E, RP – HPLC,

Abstract

A simple, selective, rapid, precise and accurate reverse phase high performance liquid chromatographic method has been developed for simultaneous estimation of vitamin A and Vitamin E in multivitamin tablet dosage form. The method was carried out on waters 2695 separation module & waters 2996 PDA detectors with Xterra C 18 column  (150 X 4.6 mm ) using Acetonitrile : methanol and water pumped at a flow rate of 1ml/min In the ratio of 85 : 15 : 5 as mobile phase at 30oC. The detection carried out at 280 nm. The intra and inter day precision was found to be less than 2% showing high precision of the assay method. The % recovery of the method was greater than 98% and RSD did not exceed 2% indicating high degree of accuracy of the proposed HPLC method. The %RSD for the robustness testing was also less than 2%. The proposed HPLC method can be used for the estimation of Vitamin A and Vitamin E in combined multivitamin tablet dosage forms.

Published

30.09.2012

How to Cite

ANURADHA.S.N., & ARUNKUMAR.S. (2012). A Validated Rp – Hplc Method For Simultaneous Estimation Of Vitamin A And Vitamin E In Multivitamin Tablet Dosage Form. International Journal of Pharma and Bio Sciences, 3(3), 322–327. Retrieved from https://ijpbs.net/index.php/journal/article/view/1488

Issue

Section

Research Articles

Categories